Shanghai Lumsail Industrial Inc

Shanghai Lumsail Industrial Inc

Manufacturer from China
Active Member
8 Years
Home / Products / Labware /

LS-17040 X-ray Fluorescence Sulfur Analyzer

LS-17040 X-ray Fluorescence Sulfur Analyzer

Ask Latest Price
Place of Origin :China
Brand Name :Lumsail
Certification :CE
Model Number :LS-17040
MOQ :1
Packaging Details :standard packing suitable for air or sea shipment
Delivery Time :3 days after payment
Payment Terms :L/C D/A D/P T/T Western Union MoneyGram
Supply Ability :200 Set/Sets / Month
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

LS-17040 X-ray Fluorescence Sulfur Analyzer

Model No.: LS-17040

LS-17040 X-ray Fluorescence Sulfur Analyzer

I. Summary and purpose
  1. Summary
  Environment pollution is attracting more and more governments and public concern. The cry for ecological environment and atmospheric environment protection is increasingly louder. The key culprit to atmospheric destruction and pollution is discharge of CO2 and SO2, which are from combustion of power fuels. Lowering down the sulfur content in the gasoline, diesel oil, heavy oils used in vehicles, ships, and airplanes will highly reduce pollution to atmosphere. Europe and our government have promulgated a series of standards on sulfur content of petroleum products to restrict its production and discharge. SO2 may also cause catalyst poisoning in petrochemical industry and form acid rain in the atmosphere.
  The instrument is specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with electrical, mechanical and microprocessor integration design, so it is rapid and accurate. It can meet the requirements of national standard GB/T 17040,SH/T0742 and GB/T11140 on repeatability and reproducibility, and it can also meet requirements of ASTM D4294-03 on these indexes. It provides a measure to determine sulfur content during petroleum or petrochemical production process.
  2. Purpose
  (1) It can be used to determine mass% of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline, and naphtha.
  (2) It can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene.
  (3) It can be used to determine total sulfur or sulfide in other liquid or solid powder samples.
II. Technical specifications and parameters.
  1. Instrument characteristics
  (1) With electrical, mechanical and microprocessor integration design, so it is compact and beautiful;
  (2) It can determine various products and in a wide measurement range. It is rapid for analysis and it only need little standard sample.
  (3) Adopts fluorescence intensity ratio analysis methods, it can make correction to temperature and pressure automatically and it can also make correction to ratio of carbon and hydrogen (C/H).
  (4) Large LCD for display; Man-machine conversation system; Sound alarm for operation mistake;
  (5) It has self-diagnostic function, so it can determine its working state and electric parameters by making counting measurement and energy spectrum measurement using reference samples.
  (6) Equipped with a RS232 serial port, it can connect with any computer or web system.
  (7) It takes disposable sample cell with Mylar film, so it can avoid cross contamination. Sample cell is made by a multifunctional pressure shaping device, so it is rapid and convenient. There is a hole on the sample cell cover and you can record sample serial number, S% (m/m), and date on the sample cell cover.
  (8) The sample holder is installed on a slide rail, so it can move out and move in automatically. It can move out from inside of the instrument for sample location and anti-leakage parts replacement. It is convenient and it can avoid any contamination to detection system.
  (9) It can save large quantity of test data. You can browse test data and calibration curves at any time.
  (10) It uses a thermal printer, so it is easy to replace printing paper.
  (11) Tightly protection measures to avoid oil leakage. The sample cell is placed on the leakage protection device. The sample cell can enter into the detection system together with the leakage protection device only during sample analysis procedures. If the instrument is not at sample analysis state, the leakage protection device will move out, so this can avoid any contamination to the detection system.
  (12) Its safe X-ray protection measures can keep people from injury of X-ray radiation.
  4. Main technical specification and parameters
  (1) Measurement range: 7 ppm to 5%
  (2) Repeatability (r): <0.02894 (X+0.1691)
  (3) Reproducibility (R): <0.1215(X+0.5555)
  (4) Detection limit: 7 ppm
  (5) Oil sample quantity: 2.5 ml (it is equal to sample depth of 4.5 mm)
  (6) Measurement time: it can preset 60, 120, 240, 300, and 600 s at random
  (7) It can make measurement automatically for single sample. Repeat times: can set 2, 3, 5, 10, and 50 at random; it will show average value and standard deviation at end of measurement.
  (8) Calibration curve numbers: it can save 9 calibration curves. 5 pieces of them are unary linear equation and 4 pieces of them are unary quadratic equation.
  (9) Working condition:
  a. Ambient temperature: 5~40℃
  b. Relative humidity: ≤85% (30 ℃)
  (10) Power supply: AC 220V±20V, 50 Hz; Rated power: 30 W
  (11) Size and weight: 468mm×368mm×136mm; 13 kg

China LS-17040 X-ray Fluorescence Sulfur Analyzer for sale

LS-17040 X-ray Fluorescence Sulfur Analyzer

Inquiry Cart 0